The whole battery system is controlled by BCM to monitor the cluster voltage and the current in real time, and distributed BMM control system with functions of collecting battery voltage, collecting battery temperature, and battery equalization to ensure the module works effectively and safely.

Get A Quote

The whole system is plug-and-play, easy to transport, install and maintain. It consists of battery module , PCS, MPPT ( optional ) , control system , fire control system , temperature control system , monitoring system one-stop integration , through the synergy of the system components to achieve effective charging and discharging , It adopts AC coupled micro grid structure , PCS , load , grid , and access to AC bus , and the corresponding control strategy is developed according to the actual case to ensure the safety of power supply and the whole battery system is controlled by BCM to monitor the cluster voltage and current in real time .

Outdoor-cabinet detail

Project IB-ESS-30P IB-ESS-60P
Cell type LFP LFP
Battery capacity (BOL) 67kwh-168kwh 118kwh-168kwh
Grid type 3P4W 3P4W
Rated charge / discharge power 30KW 60KW
Rated grid voltage and voltage range AC400V + 15% AC400V + 15%
Applicable grid frequency 50Hz+5Hz 50Hz+5Hz
Rated current 43A 86A
Power factor 1(Leading) -1 (Lagging) 1(Leading) -1 (Lagging)
Output Harmonics ≤3% ≤3%
Rated output power 30KW 60KW
Rated output voltage AC400V AC400V
Rated output frequency 50Hz 50Hz
Rated current 43A 86A
Voltage accuracy 1% 1%
Frequency accuracy 0.2Hz 0.2Hz
Dimension (W * H * D) 1897mm*2092mm*1231mm 1897mm*2092mm*1231mm
Max weight 2500kg 2500kg
IP protection rating Outdoor use Outdoor use
Seismic intensity rating 8 degree (IEC60980) 8 degree (IEC60980)
Operating temperature -20℃~50℃ -20℃~50℃
Relative humidity 0-95 % (non-condensing) 0-95 % (non-condensing)
Altitude < 2000m < 2000m
Cooling method Forced air cooling Forced air cooling.
Noise ≤ 75db ≤ 75db
System efficiency ≥85% ≥85%
Firefighting design Automatic fire suppression Automatic fire suppression
Communication interface & protocols Ethernet, Modbus TCP / IP Ethernet, Modbus TCP / IP
Maximum input module power 30KW 60KW
Rated power 60KW (Grid side 30kw, Load side 30kw) 120KW (Grid side 60kw, Load side 60kw)
Switch time ≤20ms ≤20ms
Design standard PCS: GB_T 34120, System:GB_T 36558, IEC 6293 3 PCS: GB_T 34120, System:GB_T 36558, IEC 6293 3